Liquid pharmaceutical products

 

Color measurement of liquid pharmaceutical products

 

Liquid medicines include solutions, suspensions, emulsions, syrups, drops, infusions and the contents of gel capsules. Cold remedies such as cough syrup, nasal spray or homeopathic drops as well as solutions and infusions. Doctors, pharmacists and patients also assess the effect of a drug based on its color and appearance.


If this differs from the usual appearance, it is concluded that there is a lack of quality or limited durability. In addition, compliance with pharmaceutical guidelines is important for liquid APIs, injectables and other liquid proteins. HunterLab colorimeters deliver reliably accurate color values and color numbers - even with minimal sample quantities.

Our solutions for your products:

Vista


Standard-compliant testing of color and haze

    Spectral color measurement on transparent and translucent samplesIncludes all common color numbers, including APHA/Pt-Co/Hazen, Gardner, Saybolt, JOD, EP, ADMI, Y Transmission, LOVIBOND® (RY/RYBN), Pharmacopoeias (Ph. Eur., USP, JP, PPRC) Turbidity measurement in Haze% and NTUUSB connection for keyboard, barcode reader or data carrierComprehensive QC software (ER version also possible) integratedLong-lasting LED technologyIntelligent user interface and data management
Find out more about the Vista. Request a quote!

UltraScan VIS


Color measurement of opaque and translucent samples

    Precise spectrophotometer with 10 nm resolutionOutput of CIE/ASTM color values and other indices and color numbers that meet European, American and other international pharmaceutical guidelines (with external QC software)Diffuse/8° measurement geometry Measurement of very small sample quantities possibleAvailable with 21 CFR Part 11 Compliant quality control software with Electronic Record Keeping for complete validation
Find out more about the UltraScan VIS. Request a quote!

Application example

"Color measurement of liquid biopharmaceutical products with the UltraScan VIS spectrophotometer"

In the pharmaceutical industry, the precise determination of the color of transparent liquid products is crucial in development and quality management. Accurate color measurement in transmission according to CIE and ASTM standards to qualify the color of liquid APIs, injectables and other liquid products according to international pharmaceutical guidelines is essential. In particular, the precise assignment of internationally defined color numbers must be guaranteed even with the smallest sample quantities. HunterLab color measurement offers the perfect solution to meet these requirements, providing the pharmaceutical industry with reliable, accurate color values and color numbers - even with minimal sample quantities.


The task

In addition to the exact measurement of the CIE L*a*b* color values, the reliable determination of various color numbers, such as the EP color number EP 2.2.2, the USP color number, the Apha color number or the determination of the haze value is also required Examination of pharmaceutical liquids required. When measuring color in transmission, only very small amounts of the product are often available.

Available color numbers:


    EP (European Pharmacopeia)USP (US Pharmacopeia)CS (Chinese Pharmacopeia)AphaGardnerLovibondSaybolt

The solution

With the UltraScan VIS spectrophotometer, transparent liquid pharmaceutical products can be precisely measured in transmission. In the EasyMatch QC software, in addition to the usual color scales, all color numbers commonly used in the pharmaceutical industry are also immediately calculated and displayed (see box). If you only want to use very small sample quantities, HunterLab offers various holders and cuvettes with which you can measure quantities starting from around 300 µl. The layer thickness of 1.0 cm is retained for reliable measurement.


The measurement is very simple:

    Fill the cuvette with liquid. Insert the cuvette into the holder. Trigger the measurement. Read the measured values on in the software

The accessories

The following cuvettes with matching holder:

    Rectangular cuvettes with path lengths from 2 mm to 50 mmMacro cuvettes (from 2.5 ml)Semi-micro cuvettes (from 0.6 ml)Ultra micro cuvettes (from 300 µl)


Talk to us, we will be happy to advise you!

Further information for you on the topic:

Measuring method for almost colorless liquids (Apha/Pt-Co/Hazen)

Measuring method “Determination of the EP color number according to Ph. Eur. 2.2.2”

UltraScan VIS brochure

Would you like to learn more about measuring liquids?

We help you maintain the quality standards for your product and offer your customers a consistent visual appearance. Fill out the form or contact us by email or telephone, we look forward to hearing from you!

Non-binding inquiry

Send us a message. We are happy to help you with your measurement needs.

KF 55 - URL /pharmacy-cosmetics-liquid

PRODUCTS

Our color measurement solutions are individual and diverse. In our overview you will find the right device and the right software for all applications.
Learn more

BLOG

HunterLab has been synonymous with industrial color measurement for seventy years. In our blog we provide an insight into our know-how and present specific applications.
Learn more
Share by: